Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Filters
Results by year
Table representation of search results timeline featuring number of search results per year.
Year | Number of Results |
---|---|
2004 | 1 |
2007 | 1 |
2008 | 3 |
2009 | 1 |
2024 | 0 |
Search Results
4 results
Results by year
Filters applied: . Clear all
Page 1
Photopolymerization of dental resin as restorative material using an argon laser.
Lasers Med Sci. 2008 Oct;23(4):399-406. doi: 10.1007/s10103-007-0487-1. Epub 2007 Oct 13.
Lasers Med Sci. 2008.
PMID: 17934770
A flexural modulus of 1.1 GPa and microhardness of 19.6 kg/mm(2) were achieved above the power density. No significant difference was observed (i.e., p>0.05) for water sorption and flexural strength at 700 and 1075 mW/cm(2)....
A flexural modulus of 1.1 GPa and microhardness of 19.6 kg/mm(2) were achieved above the power density. No significant difference was observ …
In vitro and in vivo studies of osteoblast cell response to a titanium-6 aluminium-4 vanadium surface modified by neodymium:yttrium-aluminium-garnet laser and silicon carbide paper.
Khosroshahi ME, Mahmoodi M, Saeedinasab H.
Khosroshahi ME, et al.
Lasers Med Sci. 2009 Nov;24(6):925-39. doi: 10.1007/s10103-008-0628-1. Epub 2008 Nov 19.
Lasers Med Sci. 2009.
PMID: 19018459
A corrosion potential of -0.21V was achieved for the LTSs compared with -0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour (i.e. wettability) than did the MTSs. No cytotoxicity effect, unlike for the MTSs, was observed for the LTSs. ...
A corrosion potential of -0.21V was achieved for the LTSs compared with -0.51V for the MTSs. The LTSs exhibited a more hydrophilic behaviour …
Item in Clipboard
Design and implementation of a new fuzzy PID controller for networked control systems.
Fadaei A, Salahshoor K.
Fadaei A, et al.
ISA Trans. 2008 Oct;47(4):351-61. doi: 10.1016/j.isatra.2008.07.003. Epub 2008 Aug 8.
ISA Trans. 2008.
PMID: 18692184
In the FB control system implementation, the desired set-point is provided by the Siemens Human-Machine Interface (HMI) software (i.e, WinCC) via an Ethernet Modbus link. While, in the NCS implementation, the cascade loop is realized in remote Siemens PLC station and the f …
In the FB control system implementation, the desired set-point is provided by the Siemens Human-Machine Interface (HMI) software (i.e …
Item in Clipboard
Interaction studies of multimode pulsed HF laser with enamel tissue using photothermal deflection and spectroscopy.
Khosroshahi ME, Ghasemi AB.
Khosroshahi ME, et al.
Lasers Med Sci. 2004;18(4):196-203. doi: 10.1007/s10103-003-0283-5. Epub 2004 Feb 11.
Lasers Med Sci. 2004.
PMID: 15042423
The main mechanism of enamel ablation at 2.78 microm where its absorption is very high is thought to be due to microexplosive evaporation of water within the enamel matrix, i.e., thermomechanical decomposition. Modelling showed that with 46% reflectivity from the enamel su …
The main mechanism of enamel ablation at 2.78 microm where its absorption is very high is thought to be due to microexplosive evaporation of …
Item in Clipboard
Cite
Cite